WPC Cladding Interior - Six Figures, and the Three That Survive a Second Building
A Cladding Package Carries Six Figures
A cladding package arrives with six figures attached to it. Two are geometry, one is a commercial minimum, and three are properties of a test. A buyer treats all six as specification, and only the first three behave that way.
The difference matters at the second project. A figure that was true of this board on this wall is not automatically true of the same board on the next one.
Which Three Travel, and Which Do Not
|
Figure |
Where the number comes from |
Does it move to the next job |
|
Face area, 0.464 m² |
160 mm × 2,900 mm |
Yes, until the board is cut shorter |
|
Boards to the m², 2.16 |
1 ÷ 0.464 |
Yes, on an uncut board |
|
Order minimum, 300 m² |
The run the line is set for |
Yes. It is the same at this section |
|
Formaldehyde |
The board, in a chamber |
No. There is no report on this build |
|
Fire class |
The board in one defined mounting |
No. The mounting is half the answer |
|
Sound reduction |
The finished wall, not the board |
No. The cavity and the seal decide it |
The first three are arithmetic. The last three are measurements, and a measurement belongs to the rig it was taken on.
A Number Without Its Rig Is Half a Document
Three things have to travel with a figure before a project can use it: the method, the assembly it was measured on, and the edition of the limit it is compared against.
Lose one of the three and the number stops being a specification. It becomes a claim, and a claim costs nothing to print.
The Board at the Mouth of the Die
Five of the eight lines come off the line itself. The other three are decided by the wall it goes onto.
|
Line item on the sheet |
To what |
What it is not |
|
Section |
160 mm wide, 24 mm deep, hollow |
A solid profile |
|
Length |
2,900 mm, or up to 5,800 mm to order |
A cut-to-size service on site |
|
Joint |
Tongue on one edge, groove on the other |
A sealed joint |
|
Face |
A film over the core, or an embossed face |
A veneer |
|
Core |
Wood fibre and HDPE |
A board with formaldehyde resin in it |
|
Fixing |
A clip seated in the tongue |
A screw through the face |
|
Trims |
Internal and external, mitred |
A closing profile for every condition |
|
Wall behind it |
Flat, dry and fixed before the first board |
Part of this product |
Eight lines, and none of them is a performance figure. A buyer who wants the eighth line answered by the board has the wrong product.
Height Divides, and the Remainder Is a Strip
A vertical run is courses of 160 mm. Whatever the finished height does not divide into comes back as a strip at the top, and the strip is the first thing a client measures.
|
Finished height |
Full courses |
Strip left |
What the strip does to the order |
|
2,200 mm |
13 |
120 mm |
One cut board per course at the top |
|
2,400 mm |
15 |
0 mm |
Nothing to cut |
|
2,600 mm |
16 |
40 mm |
A narrow band, hard to fix straight |
|
2,700 mm |
16 |
140 mm |
A band seven eighths of a board deep |
|
3,000 mm |
18 |
120 mm |
One cut board per course at the top |
|
3,300 mm |
20 |
100 mm |
A band, held under the ceiling line |
One of those heights closes on a whole course. The others put a strip overhead, and a 40 mm strip is harder to hold straight than a 140 mm one.
The Strip Is Already Priced In
A 4,000 mm wall finished at 2,700 mm is 10.8 m² and takes 25 boards across. Each board leaves the line at 2,900 mm and is cut to 2,700, so 200 mm comes off all 25.
On that wall a board covers 0.432 m² rather than 0.464. The difference is the strip, and it is paid for on every board rather than on the few that carry it.
The Joint Is a Channel, Not a Seal
Two boards meet at a tongue and a groove. The joint closes the face line and leaves a path behind it, because a groove is a channel by shape rather than by fault.
That is the reason this panel stops at a splashback and does not go into a shower. A wet room needs a tray and a waterproofed wall, and neither of those is this product.
Where the Water Goes
Water that reaches the joint runs down the back of the board to whatever the wall does with it. On a dry wall that is nothing. On a damp wall it is trapped.
A bedded joint and a sealed base change the amount that gets behind the board. They do not change what the board is, and no sealant turns a facing into a barrier.

Where the Panel Is the Wrong Answer

A shower or a wet room: the joint passes water, and no tanking layer is part of this build.
A facade: this section has no weather duty, and the outdoor board in the range is a different profile.
A wall that carries load: the panel spans nothing and braces nothing.
A fire-rated compartment: no report is held, so no class is offered here.
A curved wall: a straight board opens the tongue on the outside of the bend.
A wall out of plumb by more than the strip can hide: the error collects at the ceiling, where it is looked at.
Four Ways to Cover the Same Level Wall
|
What the site does |
What it moves |
By how much |
|
Cuts to a lower ceiling |
Coverage of every board |
0.464 drops to 0.432 m² at 2,700 mm |
|
Adds a door in the run |
The length of the run |
The run stops at the frame and starts again |
|
Leaves the wall out of plumb |
The strip at the top |
Widens by the amount of lean |
|
Fixes over battens |
How far the face stands off |
The batten depth, not the section |
|
Starts from a corner off square |
The closing board |
A rip along the return wall |
|
Orders before the drawing is fixed |
The whole quotation |
A range replaces a number |
None of the six is a defect in the board. Each one changes the count, and a count that changes after the order is a conversation about money.
Between the Extruder and the Container
|
Point |
Checked on |
Fails if |
Record |
|
Extrusion |
Wall at the tongue and the back |
The wall is thin where it joins |
Batch sheet |
|
Width |
160 mm at the face |
The face is narrow by a millimetre |
Gauge log |
|
Face |
Against the retained master |
The print drifts in repeat |
Master board |
|
Joint |
Two boards mated by hand |
The face line stays open |
Line check |
|
Cut |
Length, and a square end |
A board arrives short |
Bundle ticket |
|
Loading |
Bundles before the doors shut |
A corner is crushed |
Photographs |
A narrow face is the expensive failure. It shows at the top of the wall, after the bundles are open and half the room is up.
Terms, in the Order They Are Settled
Three hundred square metres books the line. At this section that is 1,875 running metres, or 647 pieces if they come at 2.9 m.
The quotation separates four things: board, clips, trims and packing. Freight is a fifth line, and both units appear on the sheet, running metres and square metres.
Thirty per cent books it, and the balance clears before the container is sealed. An L/C at sight is accepted where a bank prefers one.
A cut length travels as a sample, with a second piece to mate against it. The courier is at cost and the pair arrives in 3–5 days. The amount is credited against the first order.
Private label artwork can go on the bundle from 300 m². The face stays clean.
Repeat business is matched on the batch number we hold. With no number, the line's current batch is what ships.
Loading is at Ningbo or Shanghai.

The Box and the Paper

A 20' GP measures 5.898 m inside. Two boards of 2,900 mm laid end to end make 5,800 mm, leaving 98 mm at the doors, so the load lies along the floor and does not turn.
The packing list and the photographs taken at the doors travel with the goods. Ask for both before the balance is released.
A crushed bundle shown in those photographs is replaced on the following shipment. A claim raised after 7 days from arrival is handled as a separate matter.
Formaldehyde, fire class and sound reduction are not held for this build. A project that needs any of the three should raise it before the line is booked.
FAQ
Q: What sizes does the interior WPC cladding come in?
A: Standard panel is 1220 × 2440 mm at 18 or 20 mm thick. Custom sizes are cut to order.
Q: How is it installed?
A: Lock-click dry installation, no glue or cement. Cuts labour time by more than 50%. Matching keels, clips and edge trims ship with the order.
Q: What test reports can you provide?
A: CE, ISO9001 and SGS. UV test report on request. In-house tests cover water immersion, -20°C to 60°C thermal cycling and colour fastness.
Q: What warranty applies?
A: 15 years commercial, 25 years residential.
Q: Can I order below the 500-meter MOQ for a trial?
A: Standard MOQ is 500 meters per item. Trial orders are reviewed case by case - send the spec and quantity.
Hot Tags: WPC Cladding Interior, China WPC Cladding Interior manufacturers, suppliers, factory, wpc plastic board, wpc outdoor wall panel, wpc board panel, wpc decorative panels, panel de wpc, WPC Wood Panel Outdoor
